{"product_id":"aea-technology-6050-5000-swr-site-analyzer-100-khz-to-1-ghz-swr-return-loss-fdr","title":"AEA Technology 6050-5000 SWR Site Analyzer, 100 kHz to 1 GHz, SWR\/Return Loss\/FDR","description":"\u003ch2\u003eAEA Technology 6050-5000 SWR Site Analyzer\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe 6050-5000 SWR Site Analyzer verifies antenna system performance with SWR, return loss and FDR measurements in a single hand-held unit. Frequency domain reflectometry locates faults along the cable from 35 ft to over 10,000 ft (10 m to over 3,300 m), and one-button auto-tune sweeps to find the frequency where the antenna shows its best SWR or return loss. User-selectable limit lines let technicians judge pass or fail at a glance while tuning.\u003c\/p\u003e\u003cp\u003eThe instrument measures impedance from 10 to 5000 Ohms and can display resistance, reactance, impedance magnitude and angle, SWR and gamma angle across 250-point frequency plots refreshed 2.5 times per second. Automatic internal calibration with self-test, an optional external calibration and a cable-null feature support accurate measurements, and up to 50 plots and setups can be saved, recalled on the unit or uploaded to a PC with the included Site Analyzer PC Vision software. The quarter-VGA backlit color display offers user-customizable colors for daylight readability, and the NiMH battery pack provides about three hours of continuous operation.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSWR, return loss and FDR distance-to-fault from 100 kHz to 1 GHz\u003c\/li\u003e\n\u003cli\u003eOne-button auto-tune locates the antenna’s best SWR or return loss\u003c\/li\u003e\n\u003cli\u003eUser-selectable limit lines for at-a-glance pass\/fail tuning\u003c\/li\u003e\n\u003cli\u003eImpedance measurement from 10 to 5000 Ohms with multiple S11 formats\u003c\/li\u003e\n\u003cli\u003e250-point frequency display with 1 kHz resolution and 2.5 refreshes per second\u003c\/li\u003e\n\u003cli\u003eAutomatic internal calibration, self-test and cable-null feature\u003c\/li\u003e\n\u003cli\u003e50 memory slots for plots and setups with USB-2 PC transfer\u003c\/li\u003e\n\u003cli\u003eQuarter-VGA backlit color display with custom color settings\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTwo-way radio, land mobile and cellular antenna system verification\u003c\/li\u003e\n\u003cli\u003eCable fault location and distance-to-fault measurement with FDR\u003c\/li\u003e\n\u003cli\u003eAntenna tuning and sweep documentation for site commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSWR Site Analyzer (part 6050-5000)\u003c\/li\u003e\n\u003cli\u003eShort and 50 Ohm terminators\u003c\/li\u003e\n\u003cli\u003e8 AA NiMH cells (installed) and AC adapter\u003c\/li\u003e\n\u003cli\u003eBelt case with removable shoulder strap and USB cable\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide, Basic Guide and CD with operating manual, training material and Site Analyzer PC Vision software\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAEA Technology 6050-5000 SWR Site Analyzer Technical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003ctd\u003e100 kHz to 1000 MHz (1 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTuning \/ Display Resolution\u003c\/th\u003e\n\u003ctd\u003e1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Display\u003c\/th\u003e\n\u003ctd\u003e250 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRefresh Rate\u003c\/th\u003e\n\u003ctd\u003e2.5 times per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Functions\u003c\/th\u003e\n\u003ctd\u003eSWR, return loss, FDR distance-to-fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance Range\u003c\/th\u003e\n\u003ctd\u003e10 to 5000 Ohms (default 50 Ohms), accuracy ±1 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance Formats (S11)\u003c\/th\u003e\n\u003ctd\u003eResistance, reactance, Z magnitude, Z angle, SWR, gamma angle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFDR Range\u003c\/th\u003e\n\u003ctd\u003e35 ft to over 10,000 ft (10 m to over 3,300 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Speed\u003c\/th\u003e\n\u003ctd\u003e10 ms to 100 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eQuarter-VGA backlit color, user-customizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal Memory\u003c\/th\u003e\n\u003ctd\u003eUp to 50 plots and setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery \/ Runtime\u003c\/th\u003e\n\u003ctd\u003e8 AA NiMH cells, approx. 3 hours continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePC Interface\u003c\/th\u003e\n\u003ctd\u003eUSB-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eMore Cable and Antenna Analyzers\u003c\/h3\u003e\u003cp\u003eCompare with the Fluke Networks LinkIQ LIQ-100-IE Cable \u0026amp; Antenna Analyzer and the Fluke Networks DSX2-8000MI Cable \u0026amp; Antenna Analyzer, or browse the full cable and antenna analyzers category.\u003c\/p\u003e\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/aeatechnology.com\/products\/swr-site-analyzer\" target=\"_blank\" rel=\"noopener\"\u003eAEA Technology SWR Site Analyzer\u003c\/a\u003e\u003c\/p\u003e","brand":"AEA Technology","offers":[{"title":"Default Title","offer_id":67776215843003,"sku":"IMM_861141","price":1227.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/6050-5000_01_0524-600x600-1.jpg?v=1792552130","url":"https:\/\/na.indomultimeter.net\/products\/aea-technology-6050-5000-swr-site-analyzer-100-khz-to-1-ghz-swr-return-loss-fdr","provider":"Indo Multimeter","version":"1.0","type":"link"}