{"product_id":"ametek-jofra-ctc-1205-c-115-b-xxx-f-cx-dry-block-calibrator-100-to-1205c","title":"Ametek Jofra CTC-1205-C-115-B-XXX-F-CX Dry Block Calibrator, 100 to 1205°C","description":"\u003ch2\u003eAmetek Jofra CTC-1205-C-115-B-XXX-F-CX Dry Block Calibrator\u003c\/h2\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe CTC-1205 is AMETEK's compact dry-block for high-temperature sensor calibration, covering 100 to 1205°C (212 to 2201°F). The C model carries an input for a plug-and-play STS-TC reference sensor, so the true block temperature is measured and documented rather than assumed, and the reference is protected by a block limit that keeps set points inside the sensor range.\u003c\/p\u003e\n\u003cp\u003eA color display shows set point, stability status and recalibration reminders, with one-key access to set, preset, auto step and switch test functions. MVI circuitry keeps the block stable despite fluctuating shop power, and insert dimensions match the CTC-1200 so existing hole patterns can be reused.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e100 to 1205°C (212 to 2201°F) temperature range\u003c\/li\u003e\n\u003cli\u003e±2°C accuracy and ±0.1°C stability\u003c\/li\u003e\n\u003cli\u003eExternal STS-TC reference sensor input (C version)\u003c\/li\u003e\n\u003cli\u003eIntelligent reference sensors warn of overdue calibration\u003c\/li\u003e\n\u003cli\u003eOne-key set, preset, auto step and switch test functions\u003c\/li\u003e\n\u003cli\u003eMVI circuitry stabilizes output on noisy mains power\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 interface with JofraCal calibration software\u003c\/li\u003e\n\u003cli\u003eSingle-hole insert and protective carrying case included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace, oven and heat-treat sensor calibration\u003c\/li\u003e\n\u003cli\u003eDocumented high-temperature calibrations with true-value reference\u003c\/li\u003e\n\u003cli\u003eOn-site calibration where liquid baths are impractical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTool for insertion tubes\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eTest cables (1 red, 1 black)\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eJofraCal calibration software\u003c\/li\u003e\n\u003cli\u003eMains power cable (115 VAC, US\/Canada cord)\u003c\/li\u003e\n\u003cli\u003eSingle-hole insert\u003c\/li\u003e\n\u003cli\u003eProtective carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAmetek Jofra CTC-1205-C-115-B-XXX-F-CX Dry Block Calibrator Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e100 to 1205°C (212 to 2201°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±2°C (±3.6°F), internal or external reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStability\u003c\/th\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating time\u003c\/th\u003e\n\u003ctd\u003e23 to 1205°C in 50 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling time\u003c\/th\u003e\n\u003ctd\u003e1205 to 300°C and 300 to 50°C, 45 minutes each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime to stability\u003c\/th\u003e\n\u003ctd\u003e15 minutes (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImmersion depth\u003c\/th\u003e\n\u003ctd\u003e110 mm (137 mm with insulation plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWell diameter\u003c\/th\u003e\n\u003ctd\u003e27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsert\u003c\/th\u003e\n\u003ctd\u003eSingle-hole insert (XXX), 25 mm × 155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference input\u003c\/th\u003e\n\u003ctd\u003eSTS-TC external input (C version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains power\u003c\/th\u003e\n\u003ctd\u003e115 VAC (90-127 V), 650 VA, US\/Canada cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0; JofraCal software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 50°C; IP-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions \/ weight\u003c\/th\u003e\n\u003ctd\u003e248 × 148 × 390 mm; 7.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.ametekcalibration.com\/-\/media\/ametekcalibration\/download_links\/temperature\/ctc\/compact-temperature-calibrator-ctc-1205-datasheet-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCTC-1205 datasheet on ametekcalibration.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"Ametek Jofra","offers":[{"title":"Default Title","offer_id":67776842891451,"sku":"IMM_83762317","price":6564.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/ametek-jofra-ctc-1205-c-115-b-xxx-f-cx-600x600-1.jpg?v=1792555192","url":"https:\/\/na.indomultimeter.net\/products\/ametek-jofra-ctc-1205-c-115-b-xxx-f-cx-dry-block-calibrator-100-to-1205c","provider":"Indo Multimeter","version":"1.0","type":"link"}