{"product_id":"ametek-jofra-etc-125a-temperature-calibrator-10-to-125-c-portable-dry-block","title":"Ametek Jofra ETC-125A Temperature Calibrator, -10 to 125 °C, portable dry block","description":"\u003ch2\u003eAmetek Jofra ETC-125A Temperature Calibrator\u003c\/h2\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Jofra ETC (Easy Temperature Calibrator) series is designed for field verification of temperature sensing devices where time matters and a heavy lab instrument is not practical. The ETC-125A covers -10 to 125 °C in a small, lightweight body that fits in a tool box, heating at up to 100 °C per minute and stabilizing about 3 minutes after reaching set point. A one-key-one-function interface with a backlit multi-information display keeps operation simple.\u003c\/p\u003e\n\u003cp\u003ePre-drilled holes accept an insertion tube, and auto-stepping programs up to 9 temperature steps with hold times for unattended runs. A stability indicator with a 3-minute countdown, a user-selectable maximum temperature limit, RS-232 interface and JOFRAcal calibration software come standard, and the ETC-125A runs on multi-voltage 115\/230 VAC mains power.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature range -10 to 125 °C (14 to 257 °F)\u003c\/li\u003e\n\u003cli\u003e±0.5 °C accuracy, ±0.05 °C stability, 0.1 °C resolution\u003c\/li\u003e\n\u003cli\u003eHeats up to 100 °C per minute; stabilizes in about 3 minutes\u003c\/li\u003e\n\u003cli\u003eOne-key-one-function backlit multi-information display\u003c\/li\u003e\n\u003cli\u003eAuto-step with up to 9 programmable temperature steps\u003c\/li\u003e\n\u003cli\u003eStability indicator with 3-minute countdown\u003c\/li\u003e\n\u003cli\u003eRS-232 interface with JOFRAcal calibration software\u003c\/li\u003e\n\u003cli\u003eMulti-voltage 115\/230 VAC mains power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eField verification of temperature sensors and thermometers\u003c\/li\u003e\n\u003cli\u003eChecking air-conditioning and cold-chain sensors below ambient\u003c\/li\u003e\n\u003cli\u003eSensor burn-in and temperature switch testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAmetek Jofra ETC-125A Temperature Calibrator Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003ctd\u003e-10 to 125 °C (14 to 257 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStability\u003c\/th\u003e\n\u003ctd\u003e±0.05 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating rate\u003c\/th\u003e\n\u003ctd\u003eUp to 100 °C per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime to stability\u003c\/th\u003e\n\u003ctd\u003eAbout 3 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTwo-point test time\u003c\/th\u003e\n\u003ctd\u003eLess than 10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImmersion depth\u003c\/th\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsertion tube\u003c\/th\u003e\n\u003ctd\u003e1 x pre-drilled, metric or imperial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHole options\u003c\/th\u003e\n\u003ctd\u003eMetric 01: 12.5, 6, 4, 8 mm; Imperial 02: 1\/2, 3\/8, 1\/4, 5\/32 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuto-step\u003c\/th\u003e\n\u003ctd\u003eUp to 9 steps with hold times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains power\u003c\/th\u003e\n\u003ctd\u003eMulti-voltage 115 and 230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eRS-232; JOFRAcal software included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard delivery\u003c\/th\u003e\n\u003ctd\u003eDry block, RS-232 cable, shoulder strap, insertion tube and tool, traceable certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.ametekcalibration.com\/products\/temperature\/temperature-calibrators\/etc-series-easy-temperature-calibrator\" target=\"_blank\" rel=\"noopener\"\u003eAMETEK Calibration: ETC Series page\u003c\/a\u003e.\u003c\/p\u003e","brand":"Ametek Jofra","offers":[{"title":"Default Title","offer_id":67777126203579,"sku":"IMM_68188816","price":2159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/ametek-jofra-etc125a.jpg?v=1792556847","url":"https:\/\/na.indomultimeter.net\/products\/ametek-jofra-etc-125a-temperature-calibrator-10-to-125-c-portable-dry-block","provider":"Indo Multimeter","version":"1.0","type":"link"}