{"product_id":"megger-220015-dielectric-test-set-15-kv-dc","title":"Megger 220015 Dielectric Test Set, 15 kV DC","description":"\u003ch2\u003eMegger 220015 Dielectric Test Set\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eDielectric test sets measure leakage current while applying DC voltage at or above the operating level of the insulation system, helping to determine its ability to withstand overvoltages such as lightning strikes and switching surges. The 220015 is designed for equipment rated 7.5 kV and below, including power cable, switchgear and rotating machinery, and follows IEEE, ICEA, NEMA and ANSI guidelines.\u003c\/p\u003e\n\u003cp\u003eThe set is air insulated and uses no oil, making it compact and portable for field work. A zero-start interlock, current guard circuit, output overload relay and input\/output circuit breakers protect the operator and the instrument, and a strip chart recorder output is optionally available for hard-copy records.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutput 0 to 15 kV DC, continuously variable\u003c\/li\u003e\n\u003cli\u003e5 mA output for 12 minutes; 2 mA continuous (120 VAC input)\u003c\/li\u003e\n\u003cli\u003eLeakage current read from 1 to 5000 µA\u003c\/li\u003e\n\u003cli\u003e±2% full-scale accuracy\u003c\/li\u003e\n\u003cli\u003eZero-start safety interlock for high-voltage output\u003c\/li\u003e\n\u003cli\u003eCurrent guard circuit for accurate measurements\u003c\/li\u003e\n\u003cli\u003eFast charging of high-capacitance samples\u003c\/li\u003e\n\u003cli\u003eAir-insulated portable design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAcceptance and maintenance testing of motors and generators\u003c\/li\u003e\n\u003cli\u003ePower cable and switchgear insulation testing\u003c\/li\u003e\n\u003cli\u003eTransformer, insulator and capacitor DC testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord (Cat. No. 17032)\u003c\/li\u003e\n\u003cli\u003eGround connection cable, 10 ft (Cat. No. 4702)\u003c\/li\u003e\n\u003cli\u003ekV\/MΩ test record graph paper, 100-sheet pad (Cat. No. 220000)\u003c\/li\u003e\n\u003cli\u003eInstruction manual (Cat. No. AVTM22-15JA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMegger 220015 Dielectric Test Set Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage\u003c\/th\u003e\n\u003ctd\u003e0 to 15 kV DC, negative with respect to ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTest voltage ranges\u003c\/th\u003e\n\u003ctd\u003e0 to 7.5 kV and 0 to 15 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput current\u003c\/th\u003e\n\u003ctd\u003e5 mA for 12 min; 2 mA continuous (120 VAC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort circuit current\u003c\/th\u003e\n\u003ctd\u003e12 mA max, limited by circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKilovoltmeter\u003c\/th\u003e\n\u003ctd\u003e4 in taut band, 0-7.5\/0-15 kV ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent meter\u003c\/th\u003e\n\u003ctd\u003e4 in taut band, 0-5\/50\/500 µA and 5 mA ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 122 °F (-17.7 to +50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation\u003c\/th\u003e\n\u003ctd\u003eAir insulated, uses no oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety features\u003c\/th\u003e\n\u003ctd\u003eZero-start interlock, output overload relay, circuit breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions \/ weight\u003c\/th\u003e\n\u003ctd\u003e12 H x 20.5 W x 13 D in; 35.2 lb (16 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.megger.com\/en\/type\/electrical-insulation-testing\/dc-insulation-testing\" target=\"_blank\" rel=\"noopener\"\u003eDC insulation testing on megger.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"Megger","offers":[{"title":"Default Title","offer_id":67777064272059,"sku":"IMM_17229194","price":3321.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/megger-220015.jpg?v=1792556423","url":"https:\/\/na.indomultimeter.net\/products\/megger-220015-dielectric-test-set-15-kv-dc","provider":"Indo Multimeter","version":"1.0","type":"link"}