{"product_id":"megger-baker-99-ep1000-1500rc-motor-link-1500-a-split-core-cts","title":"Megger Baker 99-EP1000-1500RC Motor Link, 1500 A Split-Core CTs","description":"\u003ch2\u003eMegger Baker 99-EP1000-1500RC Motor Link, 1500 A Split-Core CTs\u003c\/h2\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eDynamic (online) motor testing inside a motor control cabinet exposes personnel to arc flash hazards. With the EP1000 installed in the MCC, testing is done from outside: the user attaches one cable from the EXP4000 to the exterior port, and the Surveyor EXP software loads the motor's test data automatically.\u003c\/p\u003e\n\u003cp\u003eThe EP1000 is passive and unpowered when the analyzer is detached, with peak operating voltage of 5 V or less. It connects directly to motors up to 1000 V and tests higher-voltage motors through MCC PTs and CTs. Typical data acquisition takes one to four minutes.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-cable connection eliminates misconnections\u003c\/li\u003e\n\u003cli\u003e3 × 1500 A split-core CTs, 600 V max, 2 × 2 in window\u003c\/li\u003e\n\u003cli\u003eMCC door connector plate and cable included\u003c\/li\u003e\n\u003cli\u003eDirect connection to motors up to 1000 V\u003c\/li\u003e\n\u003cli\u003eHigher-voltage motors tested via PTs and CTs\u003c\/li\u003e\n\u003cli\u003ePassive, un-powered when analyzer is detached\u003c\/li\u003e\n\u003cli\u003ePeak operating voltage 5 V or less\u003c\/li\u003e\n\u003cli\u003eOne to four minute data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eArc flash risk reduction during online motor monitoring\u003c\/li\u003e\n\u003cli\u003ePermanent dynamic motor monitoring installations\u003c\/li\u003e\n\u003cli\u003eContinuous electrical data capture without stopping motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMegger Baker 99-EP1000-1500RC Motor Link, 1500 A Split-Core CTs Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct ID\u003c\/th\u003e\n\u003ctd\u003e99-EP1000-1500RC (EP1000-1500 bundle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax voltage input\u003c\/th\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent transformers\u003c\/th\u003e\n\u003ctd\u003e3 × 1500 A split-core, 600 V max, 2 × 2 in ID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting hardware\u003c\/th\u003e\n\u003ctd\u003eMCC door connector plate and cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible analyzer\u003c\/th\u003e\n\u003ctd\u003eBaker EXP4000 Dynamic Motor Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating principle\u003c\/th\u003e\n\u003ctd\u003ePassive link, peak voltage ≤ 5 V during operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical data acquisition time\u003c\/th\u003e\n\u003ctd\u003e1 to 4 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMegger Baker Instruments, Fort Collins, CO, USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eManufacturer information: \u003ca href=\"https:\/\/www.megger.com\/en-us\/products\/baker-exp4000\" target=\"_blank\" rel=\"noopener\"\u003eBaker EXP4000 on megger.com\u003c\/a\u003e.\u003c\/p\u003e","brand":"Megger","offers":[{"title":"Default Title","offer_id":67776426082491,"sku":"IMM_97733525","price":758.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0777\/2635\/1547\/files\/megger-baker-99-ep1000-1500rc-600x600-1.jpg?v=1792553318","url":"https:\/\/na.indomultimeter.net\/products\/megger-baker-99-ep1000-1500rc-motor-link-1500-a-split-core-cts","provider":"Indo Multimeter","version":"1.0","type":"link"}