Ametek Jofra ETC400A115B11EX Temperature Calibrator, ETC-400 A Dry Block, 28 to 400 °C, 115 V AC

Ametek Jofra ETC400A115B11EX Temperature Calibrator, ETC-400 A Dry Block, 28 to 400 °C, 115 V AC

$1,225.00
Skip to product information
Ametek Jofra ETC400A115B11EX Temperature Calibrator, ETC-400 A Dry Block, 28 to 400 °C, 115 V AC

Ametek Jofra ETC400A115B11EX Temperature Calibrator, ETC-400 A Dry Block, 28 to 400 °C, 115 V AC

$1,225.00

Ametek Jofra ETC400A115B11EX Temperature Calibrator

Overview

The ETC-400 A is built for speed: its heating block uses a highly efficient element with the insertion holes drilled directly into the block, keeping mass low for very fast heating and cooling. A bold checkmark stability indicator confirms when the set temperature is reached, with a 3-minute countdown timer alerting the operator before the stable condition.

The one-key-one-function interface gives immediate access to temperature setting and an auto-stepping function, so field technicians can run multi-point checks without menus. Output accuracy is +0.5 °C with the internal reference, stability is ±0.15 °C, and an external JOFRA STS reference probe can be used for tighter work. RS232 communication and JOFRACAL calibration software are part of standard delivery, and this model runs on 115 V AC.

Features

  • 28 to 400 °C range at 23 °C ambient
  • Heats up to 100 °C/min and stabilizes in about 3 minutes
  • Accuracy +0.5 °C (internal reference); stability ±0.15 °C
  • Stability indicator with 3-minute countdown timer
  • One-key-one-function interface with auto-stepping
  • RS232 interface with JOFRACAL calibration software included
  • Fast cooling for rapid turnaround between test points
  • Compact and light enough to carry in a tool box

Applications

  • Field verification of temperature sensors and switches
  • Calibration of thermocouples, RTDs and thermostats
  • On-site maintenance of process temperature instrumentation

Ametek Jofra ETC400A115B11EX Temperature Calibrator Technical Specifications

Temperature range 28 to 400 °C (82 to 752 °F) at 23 °C ambient
Accuracy (internal reference) +0.5 °C
Stability ±0.15 °C (measured after 10 min of stability indication, 30 min measuring)
Display resolution 0.1 ° or 1 °C/°F
Temperature units / slope rate °C or °F; 0.1 to 9.9 °/min
Time to stability approximately 3 minutes
Heating 28 to 200 °C in 2 min; 200 to 400 °C in 3 min
Cooling 400 to 200 °C in 9 min; 200 to 50 °C in 24 min
Reference probe external JOFRA STS probe supported
Communications RS232 with JOFRACAL software
Power 115 V AC model (this configuration); other voltages available

Manufacturer information: ETC Series on ametekcalibration.com.