Overview

Selectable test voltages run from 250 V to 1000 V in 50 V steps and above 1000 V in 100 V steps, covering the full range of test voltages in IEEE 43-2000. Dielectric Absorption Ratio and Polarization Index are calculated automatically.

A guard system cancels surface leakage current, live-circuit warning shows up to 600 V AC or DC on the display, and results are stored in up to 99 labeled memory locations. The 12 V lead-acid battery delivers more than 750 tests per charge and the instrument carries a 3-year warranty.

Features

  • Test voltages 250 V to 10 kV
  • Insulation resistance up to 2 T-ohm
  • Automatic DAR and PI calculation
  • Fluke Connect wireless remote operation and real-time trending
  • Guard terminal eliminates surface leakage
  • 99 memory locations with user-defined labels
  • Leakage current 1 nA to 2 mA, capacitance 0.01 to 15 microF
  • CAT III 1000 V / CAT IV 600 V, 3-year warranty

Applications

  • Motor, generator and transformer insulation testing
  • HV and MV cable, switchgear and bus testing
  • Preventive maintenance programs with Fluke Connect reporting

What's in the Box

  • Test cables with alligator clips (red, black, green)
  • Heavy duty alligator clip leads
  • AC power cord
  • IP67 hard case
  • Quick reference card
  • USB-IR cable installation guide
  • Certificate of calibration

Fluke 1555 KIT Insulation Tester Technical Specifications

Test voltage (DC) 250 V to 10,000 V
Insulation resistance range Up to 2 T-ohm (10 kV: 200 G-ohm to 2 T-ohm range)
Accuracy (typical band) 5% of reading on specified mid ranges; 20% on high ranges
Test voltage accuracy -0%, +10% at 1 mA load
Leakage current 1 nA to 2 mA, ±(5% + 2 nA)
Capacitance 0.01 to 15.00 microF, ±(15% + 0.03 microF)
Timer 0 to 99 minutes, 1 min setting resolution
Live circuit warning 30 to 660 V AC/DC
Bar graph 0 to 2 T-ohm
Display Large digital/analog LCD, 75 x 105 mm
Power 12 V lead-acid rechargeable battery, over 750 tests per charge
Safety IEC 61010 CAT III 1000 V / CAT IV 600 V, IP40
Operating temperature -20 to 50 degC
Dimensions / weight 269 x 277 x 160 mm, 3.7 kg