Additel ADT878-160-F-220V Temperature Calibrator, -40 to 160°C, Insert F, 220V

Additel ADT878-160-F-220V Temperature Calibrator, -40 to 160°C, Insert F, 220V

$7,532.00
Skip to product information
Additel ADT878-160-F-220V Temperature Calibrator, -40 to 160°C, Insert F, 220V

Additel ADT878-160-F-220V Temperature Calibrator, -40 to 160°C, Insert F, 220V

$7,532.00

Additel ADT878-160-F-220V Temperature Calibrator

Overview

The Additel ADT878-160-F-220V Temperature Calibrator is the low-temperature model of the ADT878 Reference Dry Well series, controlling temperature from -40°C to 160°C with a display accuracy of ±0.1°C at full range and delivered with insert F and a 220 V power option. The 878 series is engineered for reference-level performance in accuracy, stability, uniformity, loading effect and hysteresis, with specifications following Euramet cg-13 guidelines. Dual-zone control and quick heating to set point keep calibration work moving.

A large color touch screen with Wi-Fi and Bluetooth capability drives the interface, and set point control by reference plus a self-calibration feature support demanding comparison calibrations. A two-channel readout measures RTDs and thermocouples and documents tasks; the Process Calibrator (PC) option adds a full HART communicator and Quick-Push connectors. Combined with the optional ADT878-TPW-KIT, the -160 model can automatically realize and maintain a triple point of water cell to check probe drift over time. Every unit ships with ISO 17025-accredited calibration including data.

Features

  • -40°C to 160°C temperature range with ±0.1°C display accuracy
  • Reference-level stability, uniformity and accuracy per Euramet cg-13
  • Large color touch screen with Wi-Fi and Bluetooth
  • Two-channel readout for RTDs and thermocouples with task documentation
  • Set point control by reference and self-calibration feature
  • Optional TPW kit for automated triple point of water realization
  • Process Calibrator option with full HART communicator
  • ISO 17025-accredited calibration with data included

Applications

  • Laboratory calibration of PRTs, thermistors and thermocouples
  • Drift checking of reference probes against a triple point of water cell
  • Field and bench comparison calibrations of temperature sensors and transmitters

Additel ADT878-160-F-220V Temperature Calibrator Technical Specifications

Temperature range -40°C to 160°C (at 23°C ambient)
Display accuracy ±0.1°C at full range
Insert model F
Power supply 220 V AC
Control Dual-zone control, set point control by reference
Display Color touch screen
Wireless Wi-Fi and Bluetooth capable
Readout Two-channel RTD and thermocouple measurement
TPW automation Optional ADT878-TPW-KIT (ADT878-160 only)
Process Calibrator option Full HART communicator, Quick-Push connectors (PC option)
Reference readout temp. coefficient ±1 ppm FS/°C
Readout accuracy, 100 Ω PRT ±0.005°C at -40°C to ±0.011°C at 160°C (probe not included)
Calibration included ISO 17025-accredited calibration with data

Manufacturer information: Additel 878 Reference Dry Well Calibrator

You may also like