AEMC PEL 103 Power and Energy Logger, 1000 V CAT III, 10,000 A
$1,109.00
AEMC PEL 103 Power and Energy Logger, 1000 V CAT III, 10,000 A
Overview
The PEL 103 is the display-equipped model of AEMC's PEL 100 series of power and energy loggers. It measures RMS voltage and current at 128 samples per cycle on every phase simultaneously, records VA, W and var plus VAh, Wh and varh with source/load indication, and stores everything on a removable SD or SDHC card.
Setup is done from the front panel or through AEMC's DataView software, which also provides real-time displays and report templates. Automatic sensor recognition, configurable PT and CT ratios and 17 supported hook-ups let one instrument cover most 50 Hz, 60 Hz, 400 Hz and DC distribution systems, and the logger satisfies NEC 220.87 logging recommendations.
Features
- Backlit four-line LCD showing three phases simultaneously
- Voltage inputs to 1000 V CAT III and 600 V CAT IV
- Current from 200 mA to 10,000 A with automatic sensor recognition
- Harmonics to the 50th order for voltage and current
- Power (VA, W, var) and energy (VAh, Wh, varh) recorded every second
- SD/SDHC card storage up to 32 GB (FAT32)
- USB 2.0, Ethernet and Bluetooth Class 1 communication
- 17 supported network hook-ups with configurable PT/CT ratios
Applications
- Energy audits and NEC 220.87 load studies
- Building and panel load monitoring before upgrades
- Verification of 50/60/400 Hz and DC distribution systems
What's in the Box
- PEL 103 logger
- Small classic tool bag
- Three MA193-10-BK current sensors
- USB cable
- Four black test leads with alligator clips
- Power cord
- 12 color-coded ID markers
- Multifix mounting system
- 2 GB SD card with USB SD-card reader
- USB stick with DataView software
- Quick start guide and user manual
AEMC PEL 103 Power and Energy Logger, 1000 V CAT III, 10,000 A Technical Specifications
| Voltage inputs | 3 channels, 4 mm safety banana jacks |
|---|---|
| Voltage range | 10 to 1000 Vrms (50/60 Hz); 17 to 1700 Vrms phase-to-phase |
| Voltage accuracy | ±0.2% of reading ±0.2 V (100 to 1000 V, 50/60 Hz) |
| Current inputs | 3 channels for AEMC probes and sensors |
| Current range | 200 mA to 10,000 A with MA193 sensors |
| Sampling | 128 samples per cycle, all phases simultaneously |
| Recording rate | 1 value per second; demand periods 1 to 60 min |
| Recorded values | V, I, W, VA, var, PF, Tan, Wh, VAh, varh, THD, harmonics 1 to 50, CF |
| Harmonics | 1st to 50th order (50/60 Hz); 1st to 7th (400 Hz) |
| Energy accuracy | ±0.5% of reading (active, apparent); ±2% reactive |
| Communication | USB 2.0, Ethernet (RJ45), Bluetooth Class 1 |
| Storage | SD/SDHC card, FAT32, up to 32 GB |
| Display | 67 × 55 mm backlit monochrome LCD |
| Power | 110/250 V external supply; 8.4 V NiMH back-up (about 5 h 30 min) |
| Dimensions / weight | 256 × 125 × 37 mm; 1 kg |
Manufacturer information: PEL 103 on aemc.com.