Ametek Jofra CTC-1205-C-115-B-XXX-F-CX Dry Block Calibrator, 100 to 1205°C

Ametek Jofra CTC-1205-C-115-B-XXX-F-CX Dry Block Calibrator, 100 to 1205°C

$6,564.00
Skip to product information
Ametek Jofra CTC-1205-C-115-B-XXX-F-CX Dry Block Calibrator, 100 to 1205°C

Ametek Jofra CTC-1205-C-115-B-XXX-F-CX Dry Block Calibrator, 100 to 1205°C

$6,564.00

Ametek Jofra CTC-1205-C-115-B-XXX-F-CX Dry Block Calibrator

Overview

The CTC-1205 is AMETEK's compact dry-block for high-temperature sensor calibration, covering 100 to 1205°C (212 to 2201°F). The C model carries an input for a plug-and-play STS-TC reference sensor, so the true block temperature is measured and documented rather than assumed, and the reference is protected by a block limit that keeps set points inside the sensor range.

A color display shows set point, stability status and recalibration reminders, with one-key access to set, preset, auto step and switch test functions. MVI circuitry keeps the block stable despite fluctuating shop power, and insert dimensions match the CTC-1200 so existing hole patterns can be reused.

Features

  • 100 to 1205°C (212 to 2201°F) temperature range
  • ±2°C accuracy and ±0.1°C stability
  • External STS-TC reference sensor input (C version)
  • Intelligent reference sensors warn of overdue calibration
  • One-key set, preset, auto step and switch test functions
  • MVI circuitry stabilizes output on noisy mains power
  • USB 2.0 interface with JofraCal calibration software
  • Single-hole insert and protective carrying case included

Applications

  • Furnace, oven and heat-treat sensor calibration
  • Documented high-temperature calibrations with true-value reference
  • On-site calibration where liquid baths are impractical

What's in the Box

  • Tool for insertion tubes
  • User manual
  • Test cables (1 red, 1 black)
  • USB cable
  • JofraCal calibration software
  • Mains power cable (115 VAC, US/Canada cord)
  • Single-hole insert
  • Protective carrying case

Ametek Jofra CTC-1205-C-115-B-XXX-F-CX Dry Block Calibrator Technical Specifications

Temperature range 100 to 1205°C (212 to 2201°F)
Accuracy ±2°C (±3.6°F), internal or external reference
Stability ±0.1°C
Heating time 23 to 1205°C in 50 minutes
Cooling time 1205 to 300°C and 300 to 50°C, 45 minutes each
Time to stability 15 minutes (typical)
Immersion depth 110 mm (137 mm with insulation plug)
Well diameter 27 mm
Insert Single-hole insert (XXX), 25 mm × 155 mm
Reference input STS-TC external input (C version)
Mains power 115 VAC (90-127 V), 650 VA, US/Canada cord
Interface USB 2.0; JofraCal software
Operating temperature 0 to 50°C; IP-10
Dimensions / weight 248 × 148 × 390 mm; 7.1 kg

Manufacturer information: CTC-1205 datasheet on ametekcalibration.com.