Ametek Jofra DTI-1000 Temperature Indicator, -200 to 750 °C, NPL Traceable (DTI1000AF)
Ametek Jofra DTI-1000 Temperature Indicator, -200 to 750 °C, NPL Traceable (DTI1000AF)
Overview
The Jofra DTI-1000 is the working standard in many national laboratories and is recommended for verifying the true temperature of any temperature calibrator, liquid bath or dry-block calibrator. The Model A input handles Pt100 or Pt25 reference sensors over two channels with a differential measurement option, and True Ohm Measurement, a 4-wire technique, eliminates the electromotive force errors caused by cables, sockets and sensors.
With user-selectable resolution of 0.1, 0.01 or 0.001 °C, °F, K or Ω, the indicator maintains ±0.004 °C one-year accuracy and ±0.03 °C system accuracy when used with STS Series sensors. The two-line VFD display, RS-232 interface, mains or 8 x 1.5 V AA battery power, and the included JofraCal software and NPL-traceable certificate (F option) make it a fully traceable reference for custody transfer and calibration work.
Features
- Temperature range -200 to 750 °C (-328 to 1382 °F)
- One-year accuracy ±0.004 °C; ±0.03 °C system accuracy with STS sensors
- User-selectable resolution 0.1, 0.01 or 0.001 °C/°F/K/Ω
- Dual-channel inputs with differential measurement option
- True Ohm Measurement eliminates EMF in cables, sockets and sensors
- Pt100/Pt25 input (Model A)
- NPL-traceable calibration certificate (DTI1000AF ordering code)
- VFD display, RS-232 interface, mains or AA battery power
Applications
- Reference thermometer for verifying liquid bath and dry-block calibrators
- Custody transfer and high-accuracy laboratory temperature measurement
- Differential temperature comparison for quality control and research
What's in the Box
- DTI-1000 A temperature indicator
- NPL-traceable calibration certificate (F option)
- USB with manual and JofraCal software
- AmeTrim adjustment software
- RS-232 cable with 9-pin adapter
- 8 x 1.5 V AA batteries
- Mains adapter
Ametek Jofra DTI-1000 Temperature Indicator, -200 to 750 °C, NPL Traceable (DTI1000AF) Technical Specifications
| Temperature range | -200 to 750 °C / -328 to 1382 °F |
|---|---|
| One-year accuracy | ±0.004 °C |
| Input accuracy (Model A, 12 months) | ±(6 ppm of reading + 1.4 mΩ) |
| System accuracy with STS sensors | ±0.03 °C |
| Resolution | 0.1, 0.01 or 0.001 °C/°F/K/Ω user selectable |
| Input channels | 2 (dual channel, differential option) |
| Input interface (Model A) | Pt100 / Pt25, 0-360 Ω |
| Termination | Gold-plated LEMO / 4 mm banana test sockets |
| Measuring units | °C, °F, K, Ω |
| Update rate | 2 / 3 / 12 s (at 0.1 / 0.01 / 0.001 resolution) |
| Display | VFD, two lines, 20 characters |
| Interface | RS-232 serial |
| Power | Mains 9 VDC / 200 mA or 8 x 1.5 V AA batteries (about 15 hours) |
| Operating ambient temperature | 0 to 50 °C |
Manufacturer information: DTI-1000 on ametekcalibration.com.