Ametek Jofra DTI-1000 Temperature Indicator, -200 to 750 °C, NPL Traceable (DTI1000AF)

Ametek Jofra DTI-1000 Temperature Indicator, -200 to 750 °C, NPL Traceable (DTI1000AF)

$2,208.00
Skip to product information
Ametek Jofra DTI-1000 Temperature Indicator, -200 to 750 °C, NPL Traceable (DTI1000AF)

Ametek Jofra DTI-1000 Temperature Indicator, -200 to 750 °C, NPL Traceable (DTI1000AF)

$2,208.00

Ametek Jofra DTI-1000 Temperature Indicator, -200 to 750 °C, NPL Traceable (DTI1000AF)

Overview

The Jofra DTI-1000 is the working standard in many national laboratories and is recommended for verifying the true temperature of any temperature calibrator, liquid bath or dry-block calibrator. The Model A input handles Pt100 or Pt25 reference sensors over two channels with a differential measurement option, and True Ohm Measurement, a 4-wire technique, eliminates the electromotive force errors caused by cables, sockets and sensors.

With user-selectable resolution of 0.1, 0.01 or 0.001 °C, °F, K or Ω, the indicator maintains ±0.004 °C one-year accuracy and ±0.03 °C system accuracy when used with STS Series sensors. The two-line VFD display, RS-232 interface, mains or 8 x 1.5 V AA battery power, and the included JofraCal software and NPL-traceable certificate (F option) make it a fully traceable reference for custody transfer and calibration work.

Features

  • Temperature range -200 to 750 °C (-328 to 1382 °F)
  • One-year accuracy ±0.004 °C; ±0.03 °C system accuracy with STS sensors
  • User-selectable resolution 0.1, 0.01 or 0.001 °C/°F/K/Ω
  • Dual-channel inputs with differential measurement option
  • True Ohm Measurement eliminates EMF in cables, sockets and sensors
  • Pt100/Pt25 input (Model A)
  • NPL-traceable calibration certificate (DTI1000AF ordering code)
  • VFD display, RS-232 interface, mains or AA battery power

Applications

  • Reference thermometer for verifying liquid bath and dry-block calibrators
  • Custody transfer and high-accuracy laboratory temperature measurement
  • Differential temperature comparison for quality control and research

What's in the Box

  • DTI-1000 A temperature indicator
  • NPL-traceable calibration certificate (F option)
  • USB with manual and JofraCal software
  • AmeTrim adjustment software
  • RS-232 cable with 9-pin adapter
  • 8 x 1.5 V AA batteries
  • Mains adapter

Ametek Jofra DTI-1000 Temperature Indicator, -200 to 750 °C, NPL Traceable (DTI1000AF) Technical Specifications

Temperature range -200 to 750 °C / -328 to 1382 °F
One-year accuracy ±0.004 °C
Input accuracy (Model A, 12 months) ±(6 ppm of reading + 1.4 mΩ)
System accuracy with STS sensors ±0.03 °C
Resolution 0.1, 0.01 or 0.001 °C/°F/K/Ω user selectable
Input channels 2 (dual channel, differential option)
Input interface (Model A) Pt100 / Pt25, 0-360 Ω
Termination Gold-plated LEMO / 4 mm banana test sockets
Measuring units °C, °F, K, Ω
Update rate 2 / 3 / 12 s (at 0.1 / 0.01 / 0.001 resolution)
Display VFD, two lines, 20 characters
Interface RS-232 serial
Power Mains 9 VDC / 200 mA or 8 x 1.5 V AA batteries (about 15 hours)
Operating ambient temperature 0 to 50 °C

Manufacturer information: DTI-1000 on ametekcalibration.com.