Ametek Jofra ETC-125A Temperature Calibrator, -10 to 125 °C, portable dry block

Ametek Jofra ETC-125A Temperature Calibrator, -10 to 125 °C, portable dry block

$2,159.00
Skip to product information
Ametek Jofra ETC-125A Temperature Calibrator, -10 to 125 °C, portable dry block

Ametek Jofra ETC-125A Temperature Calibrator, -10 to 125 °C, portable dry block

$2,159.00

Ametek Jofra ETC-125A Temperature Calibrator

Overview

The Jofra ETC (Easy Temperature Calibrator) series is designed for field verification of temperature sensing devices where time matters and a heavy lab instrument is not practical. The ETC-125A covers -10 to 125 °C in a small, lightweight body that fits in a tool box, heating at up to 100 °C per minute and stabilizing about 3 minutes after reaching set point. A one-key-one-function interface with a backlit multi-information display keeps operation simple.

Pre-drilled holes accept an insertion tube, and auto-stepping programs up to 9 temperature steps with hold times for unattended runs. A stability indicator with a 3-minute countdown, a user-selectable maximum temperature limit, RS-232 interface and JOFRAcal calibration software come standard, and the ETC-125A runs on multi-voltage 115/230 VAC mains power.

Features

  • Temperature range -10 to 125 °C (14 to 257 °F)
  • ±0.5 °C accuracy, ±0.05 °C stability, 0.1 °C resolution
  • Heats up to 100 °C per minute; stabilizes in about 3 minutes
  • One-key-one-function backlit multi-information display
  • Auto-step with up to 9 programmable temperature steps
  • Stability indicator with 3-minute countdown
  • RS-232 interface with JOFRAcal calibration software
  • Multi-voltage 115/230 VAC mains power

Applications

  • Field verification of temperature sensors and thermometers
  • Checking air-conditioning and cold-chain sensors below ambient
  • Sensor burn-in and temperature switch testing

Ametek Jofra ETC-125A Temperature Calibrator Technical Specifications

Temperature range -10 to 125 °C (14 to 257 °F)
Accuracy ±0.5 °C
Stability ±0.05 °C
Resolution 0.1 °C / 0.1 °F
Heating rate Up to 100 °C per minute
Time to stability About 3 minutes
Two-point test time Less than 10 minutes
Immersion depth 110 mm
Insertion tube 1 x pre-drilled, metric or imperial
Hole options Metric 01: 12.5, 6, 4, 8 mm; Imperial 02: 1/2, 3/8, 1/4, 5/32 in
Auto-step Up to 9 steps with hold times
Mains power Multi-voltage 115 and 230 VAC
Interface RS-232; JOFRAcal software included
Standard delivery Dry block, RS-232 cable, shoulder strap, insertion tube and tool, traceable certificate

Manufacturer information: AMETEK Calibration: ETC Series page.