Overview

The HPC600 generates pressure and vacuum from a single key press with its built-in electrical pump system, and a vent valve with pressure/vacuum selector plus a fine-volume adjuster make setting pressures quick. Fully temperature compensation from -10 to 50 °C keeps laboratory accuracy available in the field.

Beyond pressure, it measures and sources mA with a 24 V loop supply, reads voltage, and offers 15 pressure units, % error calculation, leak test and pressure switch test functions. JOFRA APM external pressure modules extend the range to over 35 models with accuracy up to 0.01% FS.

Features

  • Built-in electrical pressure and vacuum pump
  • Compound range -0.82 to 20 bar (-12 to 300 psi)
  • Accuracy ±0.020% rdg + 0.015% FS (18 to 28 °C)
  • Complete mA loop calibrator with 24 V loop supply
  • Pt100 high-accuracy thermometer input
  • 15 selectable pressure engineering units
  • Leak test, % error and pressure switch test functions
  • External JOFRA APM modules up to 0.01% FS

Applications

  • Pressure transmitter and gauge calibration in the field
  • mA loop transmitter calibration and switch testing
  • Custody transfer and process calibration jobs

What's in the Box

  • Handheld calibrator with hose and fittings
  • Padded soft case
  • International traceable calibration certificate (pressure, vacuum and electrical)

Ametek Jofra HPC600 Pressure Calibrator Technical Specifications

Pressure range (020C) -0.82 to 20 bar / -12 to 300 psi compound
Pressure accuracy, reference (18 to 28 °C) ±0.020% RDG + 0.015% F.S.
Pressure accuracy, ambient (-10 to 50 °C) ±0.030% RDG + 0.015% F.S.
Vacuum accuracy ±0.025% F.S. (reference temperature)
Engineering units 15 user-selectable
Electrical mA/V measure and source, 24 VDC loop supply
Temperature input Pt100 sensor (optional port)
Pressure connections 1/8 in NPT/BSP female, 300 series stainless steel
Temperature compensation -10 to 50 °C (14 to 122 °F)
Communication RS-232 for PC or APM module
External modules JOFRA APM series, 35+ models, up to 0.01% F.S.