Ametek Jofra PTC660A Temperature Calibrator, 33 to 660 °C, 115 VAC

Ametek Jofra PTC660A Temperature Calibrator, 33 to 660 °C, 115 VAC

$5,251.00
Skip to product information
Ametek Jofra PTC660A Temperature Calibrator, 33 to 660 °C, 115 VAC

Ametek Jofra PTC660A Temperature Calibrator, 33 to 660 °C, 115 VAC

$5,251.00

Ametek Jofra PTC660A Temperature Calibrator

Overview

The PTC-660 A is the entry model of JOFRA's PTC professional dry-block calibrator series. It heats from 33 to 660 °C, and its patented active dual-zone block keeps temperature homogenous across the calibration zone, so sensors down the length of the well see closely matched conditions.

A large 5.7-inch colour VGA display keeps SET, READ, TRUE and sensor-under-test values visible during calibration, and MVI (Mains Power Variance Immunity) holds temperature stable even on fluctuating supplies. USB 2.0 communication, bundled JofraCal software, IRI recalibration reminders and multi-hole insert kits make field calibration efficient; this unit is the 115 V version.

Features

  • 33 to 660 °C dry-block temperature range
  • Patented active dual-zone heating technology
  • ±0.04 °C stability and 0.001 ° set resolution
  • 5.7-inch full-colour VGA display
  • MVI (Mains Power Variance Immunity) for stable control
  • USB 2.0 port with JofraCal calibration software included
  • IRI intelligent recalibration information
  • Multi-hole metric (3 to 12 mm) and imperial (1/8 to 1/2 in) insert kits

Applications

  • RTD, thermocouple and transmitter calibration
  • Industrial and pharmaceutical process sensor checking
  • Temperature switch testing

Ametek Jofra PTC660A Temperature Calibrator Technical Specifications

Model PTC-660 A (basic model, without inputs)
Temperature range 33 to 660 °C (91 to 1220 °F)
Stability ±0.04 °C (±0.072 °F)
Accuracy, internal reference ±0.30 °C from 33 to 420 °C; ±0.50 °C from 420 to 660 °C
Radial homogeneity 0.1 °C (difference between holes)
Display resolution (user selectable) 1 °, 0.1 °, or 0.01 °
Heating time 33 to 660 °C in about 20 minutes
Cooling time 660 to 100 °C in about 36 minutes; 100 to 50 °C in about 15 minutes
Well diameter / immersion depth 25 mm / 150 mm
Mains 115 V (90 to 127 V), 50/60 Hz, max 1150 VA
Communications USB 2.0 device port
Dimensions (L × W × H) 362 × 171 × 363 mm
Weight 8.9 kg (19.6 lb)
Operating environment 0 to 40 °C, 0 to 90% RH, IP-10

Manufacturer information: PTC-155/350/425/660 datasheet on ametekcalibration.com.

You may also like