Amprobe AM-560 HVAC Multimeter, 1000 V AC/DC, CAT IV 600 V

Amprobe AM-560 HVAC Multimeter, 1000 V AC/DC, CAT IV 600 V

$67.00
Skip to product information
Amprobe AM-560 HVAC Multimeter, 1000 V AC/DC, CAT IV 600 V

Amprobe AM-560 HVAC Multimeter, 1000 V AC/DC, CAT IV 600 V

$67.00

Amprobe AM-560 HVAC Multimeter

Overview

Dual thermocouple inputs take simultaneous low-side and high-side temperature readings from -40 to 1000 °C (-40 to 1832 °F), while a low pass filter improves voltage accuracy on variable frequency drives. A microamps range supports flame sensor troubleshooting and non-contact voltage detection adds safety before probing.

The AM-560 adds peak hold (crest) for capturing voltage or current surges, MIN/MAX recording, relative zero, data hold and a dual display. Supplied accessories include two Type-K probes, a temperature adaptor, test leads and a carrying case.

Features

  • 6000-count true RMS autoranging display
  • AC/DC voltage to 1000 V; AC/DC current to 10 A
  • Dual thermocouple inputs, -40 to 1000 °C
  • Low pass filter for variable frequency drives
  • Microamps range for flame sensor testing
  • Non-contact voltage detection
  • Peak hold, MIN/MAX and relative zero
  • CAT IV 600 V / CAT III 1000 V safety rating

Applications

  • HVAC differential temperature and electrical checks
  • Variable frequency drive voltage measurement
  • Flame sensor and motor capacitor troubleshooting

What's in the Box

  • AM-560 multimeter
  • 9 V (6F22) battery (installed)
  • Test leads
  • 2 × Type-K temperature probes
  • Temperature adaptor
  • Velcro strap and carrying case

Amprobe AM-560 HVAC Multimeter Technical Specifications

Display 6000 count LCD, dual display
AC voltage 6 V to 1000 V, ±(1.0% rdg + 3 LSD)
DC voltage 600 mV to 1000 V, ±(0.5% rdg + 2 LSD)
AC/DC current 600 µA to 10 A
Resistance 600 Ω to 60 MΩ, ±(1.0% rdg + 2 LSD)
Capacitance 60 nF to 60 mF, ±(3.0% rdg + 5 LSD)
Frequency 60 Hz to 60 MHz, ±(0.1% rdg + 3 LSD)
Temperature -40 to 1000 °C, dual thermocouple
Duty cycle 10.00% to 90.00%
Safety rating CAT IV 600 V, CAT III 1000 V

Manufacturer information: AM-560 on amprobe.com.